top of page

​UV Adhesives and Coatings

​​

Electronic Application

 

Name​ ​ Cure Type Fixed Time Water Absorp. 2hrs. @100c Viscosity Durometer Hardness  LAP Shear Strength (PolyCarb to PolyCarb) PSI Temp. Range TDS
MP531001E​ ​ UV 1 second       4.7% 300-400 cp D30 755 -60 to 300 F TDS​
MP531002E ​ UV 1 second       4.7% 500-1000 cp D30 810 -60 to 300 F TDS
MP531003E ​ UV 1 second       4.7% 3500-5500 cp D30 860 -60 to 300 F TDS
MP531004E ​ UV 1 second        4.7% 300-400 cp D30 755 -60 to 300 F TDS
MP531005E ​ UV 1 second        4.7% 500-1000 cp D30 810 -60 to 300 F TDS
MP531006E ​ UV 1 second        4.7% 2800-4000 cp D30 860 -60 to 300 F TDS
                   

 

We Bond at the Speed of Light!

Medical Device Applications

​

Name​ Passed ISO 10993 Cytotoxicity Testing Cure Type Fixed Time Water Absorp. 2hrs. @ 100 C Viscosity Durometer Hardness Tensile Strength PSI Temp. Range TDS
MP531101M​ Yes UV 0.5 Seconds 3.0% 110-170cps D72 5800 -60 to 300 F ​TDS
MP531102M Yes UV 0.5 seconds 3.0% 180-270 cp D70 4400 -60 to 300 F ​TDS
MP531103M Yes UV 0.5 seconds 3.0% 300-400 cp D70 3650 -60 to 300 F ​TDS
MP531104M Yes UV 0.5 Seconds 3.0% 440-550 cp D65 3450 -60 to 300 F ​TDS
MP531105M Yes UV 0.5 Seconds 3.6% 3000-5000 cp D70 3600 -60 to 300 F ​TDS
MP531106M Yes UV 0.5 Seconds 3.0% 110-170 cp D72 5800 -60 to 300 F ​TDS
MP531107M Yes UV 0.5 Seconds 3.0% 180-270 cp D70 3650 -60 to 300 F ​TDS
MP531108M Yes UV 0.5 seconds 3.0% 300-400 cp D70 3650 -60 to 300 F ​TDS
MP531109M Yes UV 0.5 Seconds 3.0% 400-550cp D65 3450 -60 to 300 F ​TDS
MP531110M Yes UV 0.5 seconds 3.6% 3000-5000 cp D70 3600 -60 to 300 F ​TDS
MP531701M Yes UV 0.5 seconds 3.7% 300-420 cp A45 ​ -60 to 300 F ​TDS
MP532109M Yes UV 0.5 seconds 2.9% 600-1000 cp D68 4050 -60 to 300 F ​TDS
MP532110M Yes UV 0.5 seconds 2.9% 600-1000 cp D68 4050 -60 to 300 F ​TDS
MP532111M Yes UV 0.5 seconds 3.6% 6000-12000 cp D70 3200 -60 to 300 F ​TDS
MP532112M ​Yes ​UV 0.5 seconds 3.6% 6000-12000 cp D70 3200 -60 to 300 F ​TDS
                   

 

General Industrial Applications

 

 

Name Passed ISO 10993 Cytotoxicity Testing Cure Type Fixed Time Water Absorp. 2hrs @ 100 C Viscosity Durometer Hardness Lap Shear Strength PSI Polycarb. Temp. Range TDS​
MP531001I​ Yes UV 1 second 4.7% 300-400 cp D30 760 -60 to 300 F TDS​
MP531002I Yes​ UV 1 second 4.7% 500-100 cp D30 810 -60 to 300 F TDS​
MP531003I Yes UV 1 second 4.7% 3500-5500 cp D30 860 -60 to 300 F TDS​
MP531004I Yes UV 1 second 4.7% 300-400 cp D30 760 -60 to 300 F TDS​
MP531005I Yes UV 1 second 4.7% 500-100 cp D30 810 -60 to 300 F TDS
MP531006I Yes UV 1 second 4.7% 2800-4000 cp D30 860 -60 to 300 F TDS
MP531009I Yes UV 1 second 4.7% 600-1000 cp D30 1050 -60 to 300 F TDS
MP531101I Yes UV 0.5 seconds 3.0% 110-170 cp D72

Tensile Strength PSI

5800

-60 to 300 F TDS
MP531102I Yes UV 0.5 Seconds 3.0% 180-270 cp D70 4400 -60 to 300 F TDS​
MP531103I Yes UV 0.5 seconds 3.0% 300-400 cp D70 3650 -60 to 300 F TDS
MP531104I Yes UV 0.5 seconds 3.0% 440-550 cp D65 3450 -60 to 300 F TDS
MP531105I Yes UV 0.5 seconds 3.0% 3000-5000 cp D70 3570 -60 to 300 F TDS
MP531106I Yes UV 0.5 seconds 3.0% 110-170 cp D72 5800 -60 to 300 F TDS
MP531107I Yes UV 0.5 seconds 3.0% 180-270 cp D70 4400 -60 to 300 F TDS
MP531108I Yes UV 0.5 seconds 3.0% 280-400 cp D70 3650 -60 to 300 F TDS​
MP531109I Yes UV 0.5 seconds 3.0% 440-550 cp D65 3450 -60 to 300 F TDS
MP531110I Yes UV 0.5 seconds 3.0% 3000-5000 cp D70 3600 -60 to 300 F TDS
MP531201I Yes UV 0.5 seconds 0.7% 22000-37000 cp D35 Tg at 30C -60 to 300 F TDS

 

Copyright© 2013 Adhesive Systems, Inc.   All rights reserved.